203 research outputs found

    One-step dual purpose joining technique

    Get PDF
    This fastener used in induction heating is a wire screen basically of an eddy current carrying material such as carbon steel. Selected wires in the screen are copper, sheathed in an insulating material. The screen is placed between two sheets of thermoplastics. When inductively heated, the composite softens and flows around the apertures of the screen. After this heating and joining, the copper wires may be used to conduct electricity

    Effects of control laws and relaxed static stability on vertical ride quality of flexible aircraft

    Get PDF
    State variable techniques are utilized to generate the RMS vertical load factors for the B-52H and B-1 bombers at low level, mission critical, cruise conditions. A ride quality index is proposed to provide meaningful comparisons between different controls or conditions. Ride quality is shown to be relatively invariant under various popular control laws. Handling quality variations are shown to be major contributors to ride quality variations on both vehicles. Relaxed static stability is artificially implemented on the study vehicles to investigate its effects on ride quality. The B-52H ride quality is generally degraded when handling characteristics are automatically restored by a feedback control to the original values from relaxed stability conditions. The B-1 airplane shows little ride quality sensitivity to the same analysis due to the small rigid body contribution to load factors at the flight condition investigated

    Cavity Optomechanical Magnetometer

    Get PDF
    A cavity optomechanical magnetometer is demonstrated where the magnetic field induced expansion of a magnetostrictive material is transduced onto the physical structure of a highly compliant optical microresonator. The resulting motion is read out optically with ultra-high sensitivity. Detecting the magnetostrictive deformation of Terfenol-D with a toroidal whispering gallery mode (TWGM) resonator a peak sensitivity of 400 nT/Hz^.5 was achieved with theoretical modelling predicting that sensitivities of up to 500 fT/Hz^.5 may be possible. This chip-based magnetometer combines high-sensitivity and large dynamic range with small size and room temperature operation

    The Charlotte (TM) intra-vehicular robot

    Get PDF
    NASA has identified telerobotics and telescience as essential technologies to reduce the crew extra-vehicular activity (EVA) and intra-vehicular activity (IVA) workloads. Under this project, we are developing and flight testing a novel IVA robot to relieve the crew of tedious and routine tasks. Through ground telerobotic control of this robot, we will enable ground researchers to routinely interact with experiments in space. Our approach is to develop an IVA robot system incrementally by employing a series of flight tests with increasing complexity. This approach has the advantages of providing an early IVA capability that can assist the crew, demonstrate capabilities that ground researchers can be confident of in planning for future experiments, and allow incremental refinement of system capabilities and insertion of new technology. In parallel with this approach to flight testing, we seek to establish ground test beds, in which the requirements of payload experimenters can be further investigated. In 1993 we reviewed manifested SpaceHab experiments and defined IVA robot requirements to assist in their operation. We also examined previous IVA robot designs and assessed them against flight requirements. We rejected previous design concepts on the basis of threat to crew safety, operability, and maintainability. Based on this insight, we developed an entirely new concept for IVA robotics, the CHARLOTTE robot system. Ground based testing of a prototype version of the system has already proven its ability to perform most common tasks demanded of the crew, including operation of switches, buttons, knobs, dials, and performing video surveys of experiments and switch panels

    Sensitivity of cavity optomechanical field sensors

    Get PDF
    This article presents a technique for modeling cavity optomechanical field sensors. A magnetic or electric field induces a spatially varying strain across the sensor. The effect of this strain is accounted for by separating the mechanical motion of the sensor into eigenmodes, each modeled by a simple harmonic oscillator. The force induced on each oscillator can then be determined from an overlap integral between strain and the corresponding eigenmode, with the optomechanical coupling strength determining the ultimate resolution with which this force can be detected

    Modulation of extracellular ISG15 signaling by pathogens and viral effector proteins

    Get PDF
    ISG15 is a ubiquitin-like modifier that also functions extracellularly, signaling through the LFA-1 integrin to promote interferon (IFN)-γ release from natural killer (NK) and T cells. The signals that lead to the production of extracellular ISG15 and the relationship between its two core functions remain unclear. We show that both epithelial cells and lymphocytes can secrete ISG15, which then signals in either an autocrine or paracrine manner to LFA-1-expressing cells. Microbial pathogens and Toll-like receptor (TLR) agonists result in both IFN-β-dependent and -independent secretion of ISG15, and residues required for ISG15 secretion are mapped. Intracellular ISGylation inhibits secretion, and viral effector proteins, influenza B NS1, and viral de-ISGylases, including SARS-CoV-2 P

    Tissue Compatibility of Two Biodegradable Tubular Scaffolds Implanted Adjacent to Skin or Buccal Mucosa in Mice

    Full text link
    Radiation therapy for cancer in the head and neck region leads to a marked loss of salivary gland parenchyma, resulting in a severe reduction of salivary secretions. Currently, there is no satisfactory treatment for these patients. To address this problem, we are using both tissue engineering and gene transfer principles to develop an orally implantable, artificial fluid-secreting device. In the present study, we examined the tissue compatibility of two biodegradable substrata potentially useful in fabricating such a device. We implanted in Balb/c mice tubular scaffolds of poly-L-lactic acid (PLLA), poly-glycolic acid coated with PLLA (PGA/PLLA), or nothing (sham-operated controls) either beneath the skin on the back, a site widely used in earlier toxicity and biocompatibility studies, or adjacent to the buccal mucosa, a site quite different functionally and immunologically. At 1, 3, 7, 14, and 28 days postimplantation, implant sites were examined histologically, and systemic responses were assessed by conventional clinical chemistry and hematology analyses. Inflammatory responses in the connective tissue were similar regardless of site or type of polymer implant used. However, inflammatory reactions were shorter and without epithelioid and giant cells in sham-operated controls. Also, biodegradation proceeded more slowly with the PLLA tubules than with the PGA/PLLA tubules. No significant changes in clinical chemistry and hematology were seen due to the implantation of tubular scaffolds. These results indicate that the tissue responses to PLLA and PGA/PLLA scaffolds are generally similar in areas subjacent to skin in the back and oral cavity. However, these studies also identified several potentially significant concerns that must be addressed prior to initiating any clinical applications of this device.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/63126/1/107632702760240562.pd

    Induction heating coupler

    Get PDF
    An induction heating device includes a handle having a hollow interior and two opposite ends, a wrist connected to one end of the handle, a U-shaped pole piece having two spaced apart ends, a tank circuit including an induction coil wrapped around the pole piece and a capacitor connected to the induction coil, a head connected to the wrist and including a housing for receiving the U-shaped pole piece, the two spaced apart ends of the pole piece extending outwardely beyond the housing, and a power source connected to the tank circuit. When the tank circuit is energized and a susceptor is placed in juxtaposition to the ends of the U-shaped pole piece, the susceptor is heated by induction heating due to magnetic flux passing between the two ends of the pole piece

    Induction heating coupler and annealer

    Get PDF
    An induction heating device includes a handle having a hollow interior and two opposite ends, a wrist connected to one end of the handle, a U-shaped pole piece having- two spaced apart ends, a tank circuit including an induction coil wrapped around the pole piece and a capacitor connected to the induction coil, a head connected to the wrist and including a housing for receiving the U-shaped pole piece, the two spaced apart ends of the pole piece extending outwardly beyond the housing, and a power source connected to the tank circuit. When the tank circuit is energized and a susceptor is placed in juxtaposition to the ends of the U-shaped pole piece, the susceptor is heated by induction heating due to a magnetic flux passing between the two ends of the pole piece

    6-Thioguanine blocks SARS-CoV-2 replication by inhibition of PLpro

    Get PDF
    The emergence of SARS-CoV-2 has led to a global health crisis that, in addition to vaccines and immunomodulatory therapies, calls for the identification of antiviral therapeutics. The papain-like protease (PLpro) activity of nsp3 is an attractive drug target as it is essential for viral polyprotein cleavage and for deconjugation of ISG15, an antiviral ubiquitin-like protein. We show here that 6-Thioguanine (6-TG), an orally available and widely available generic drug, inhibits SARS-CoV-2 replication in Vero-E6 cells with an EC50 of approximately 2 μM. 6-TG also inhibited PLpro-catalyzed polyprotein cleavage and de-ISGylation in cells and inhibited proteolytic activity of the purified PLpro domai
    • …
    corecore